TDA38740A-0000

Mfr. #:
TDA38740A-0000
Mfr.:
Infineon Technologies
Product Type:
Buck Converter
Series:
OptiMOS™ IPOL
Package / Case:
36-IQFN
Description:
40 A PMBus synchronous buck regulator, 4.5–17 V input with internal bias, 36-IQFN

Product Attributes

AttributeValue
TopologySingle-phase synchronous buck
Input Voltage4.5–17 V with internal LDO; 3–17 V with external VCC
Output Current40 A maximum continuous; subject to temperature derating and OCP threshold tolerance
Output Voltage0.25–2.56 V at VOUT_SCALE_LOOP 1:1; 0.5–5.12 V at 1:2 with external divider; maximum also limited by minimum off-time
Switching Frequency400 kHz–2 MHz, 200 kHz steps excluding 1.6 MHz
Control MethodFast constant-on-time (COT)
ProtectionOvercurrent, output overvoltage/undervoltage and overtemperature
Number Of Outputs1
Bias Supply Voltage4.5–5.5 V external VCC
InterfacePMBus / I2C, up to 1 MHz
Startup ConfigurationGeneric PMBus-controlled -0000; pin strapping disabled, default VOUT_COMMAND = 0 V
TelemetryVoltage, current, temperature and power over PMBus
Junction Temperature−40 °C to +125 °C operating
Package DetailsPG-IQFN-36-3, 5 × 6 mm

Product Details

TDA38740A-0000 is a 40 A synchronous buck regulator for point-of-load supplies in server, storage and communications equipment. It integrates the PWM controller, OptiMOS™ MOSFETs and bootstrap diode. Fast constant-on-time control supports rapid load changes, while the external inductor and capacitors complete the power-conversion stage.

The -0000 version uses a generic PMBus-controlled configuration with pin strapping disabled. Its default VOUT_COMMAND is 0 V, so the board must set the desired output before the regulator produces a rail. This configuration matters when replacing a pin-configured -0020 or -0030 device. Output programming must also agree with the feedback network: VOUT_SCALE_LOOP 1:1 covers 0.25–2.56 V, while 1:2 uses an external divider for 0.5–5.12 V.

The 40 A continuous rating remains subject to the documented thermal derating and current-limit tolerance. Check the intended input/output ratio and switching frequency together, because minimum off-time limits the achievable output voltage. Board heat removal and the selected operating point determine usable load current; a protection threshold alone does not establish continuous capacity.

Quality · Shipping · Payment

Details

Quality Confirmation

Pre-shipment checks cover batch, package, labels and markings. Inspection photos and third-party inspection support are available on request.

Shipping

Worldwide delivery is supported. Carrier, lead time and buyer-appointed forwarder requirements are confirmed with the quotation.

Payment

Payment method, currency and trade terms are subject to the formal quotation or proforma invoice.